Designation:
The generator is designed for supplying electric systems of aircraft
with direct current.
Working temperature -600C to +500C, altitude up to 15000 m.
Description:
It is a shunt four - pole DC generator, designed for drive by aircraft
engine through a reduction gearing.
The additional equipment :
- voltage regulator type RWN-170
- cut-out type DMR-400D
- loading resistor type RS-7
- filter type SF-3000 or SF-3000R
Technical data:
Rated voltage 28.5 V
Power output (at 30 V) 3000 W
Rated loading current 100 A
Working RPM range 3800 to 6500 rev/min
Type of duty continous
Current overload 50% (for 2 min)
Weight max. 12.3 kG
|