Aplication
The instument is designed for aeroplanes and helicopters.
Technical data
Measuring range:
(WRm-15-PAB) . . . . . . . up to 15 m/s
accuracy: ±1 m/s for the rate 5 m/s
±2 m/s for the rate 15 m/s
(WRm-15-KKK) . . . . . . . up to 20 knots
accuracy: ±2 knots for the rate 10 knots
±4 knots for the rate 20 knots
(WRm-15-FFF) . . . . . . . up to 3000 feet/min
accuracy: ±500 feet for the rate 1000 feet/min
±1000 feet for the rate 2000 feet/min
Working temperature: . . . . . . . -54°C...+70°C
Weight: without thermo-flask . . 0,44 kg
Thermo-flask capacity: . . . . . . 420 cm
Diameter: . . . . . . . . . . . . . . . 80 mm
Overall length of instrument with terminal for connecting
an elastic hose - 123 mm.
Black metal housing, white markings on matt black background.
The instrument meets requirements of BS 3G.100.
|
 |